Orifice (mm): 4.5mm
Pressure range(bar): 0-7 bar
Seal type: FKM
Voltage: 24V DC 8Watts
Coil encapsulation: IXEF
Connector type required: CNE Large sold separately
The
maximum allowable pressure for most media is 17 bar**, although the
maximum pressure for steam is 5 bar. (gauge pressure) as above this the temperature of the steam
would exceed the maximum allowable temperature for the seals.
Orifice
size from 2.8 mm to 4.5 mm, all the valves will operate from zero
pressure; the smallest standard orifice of 2.8 mm allows the valve to
operate up to 17 bar.** Maximum operating pressure depends on the
orifice size (larger orifice sizes reduce the maximum operating
pressure), type of coil used and the use of AC or DC voltages.
Options and Accessories (call Beta Valve sales office for details):
Hose holder
Chemical nickel plating
Filter on inlet
** Dependent on valve/coil combination chosen.